Here we will discuss, the difference between distribution transformer and power transformer. The difference is categorized on the factors like the type of network used, location of installation, usage either for low voltages or high voltages., the various ratings in which the power and the distribution transformers are available in the market.

 

The Basic Difference between the Power Transformer and Distribution Transformer

 

Along with this, the designing efficiency and the designing of the core, the types of losses occurring in the transformer, their operating conditions, and various applications are also important parameters.

The difference between the two transformers is given below:

 

BASIS OF DIFFERENCE

POWER TRANSFORMER

DISTRIBUTION TRANSFORMER

Type of network

It is used in transmission network of higher voltages

It is used in the distribution network for lower voltages.

Availability of ratings

400 kV, 200 kV, 110 kV , 66 kV, 33 kV.

11 Kv, 6.6 Kv, 3.3 Kv, 440 V,230 V

Maximum rating of usage

Power transformers are used for rating above 200 MVA

Distribution transformers are used for rating less than 200 MVA

Size

Larger in size as compared of distribution transformers

Smaller in size

Designed Efficiency

Designed for maximum efficiency of 100%

Designed for 50-70% efficiency

Efficiency formula

Efficiency is measured as the ratio of output to the input power

Here All Day Efficiency is considered. It is the ratio of output in kilowatt hour (kWh) or watt hour (Wh) to the input in kWh or Wh of a transformer over 24 hours.

Application

Used in generating stations and transmission substations

Used in distribution stations, also for industrial and domestic purposes

Losses

Copper and iron losses take place throughout the day

Iron losses take place for 24 hours and copper losses are based on load cycle

Load fluctuation

In power transformer the load fluctuations are very less

Load fluctuations are very high

Operating condition

Always operated at full load

Operated at load less than full load as load cycle fluctuates

Considering time

It is independent of time

It is time dependent

Flux density

In power transformer flux density is higher

As compared to power transformer the flux density is lower in distribution transformer

Designing of the core

Designed to utilize the core for maximum and will operate near to the saturation point of the B-H curve, which helps to bring down the mass of core

As compared to power transformer the flux density is lower in distribution transformer

Usage

Used to step up and step down voltages

Used as an end user connectivity

 

View the key comparison between power and distribution transformer with Yuebian transformers or just scrow down to learn more.

 

Power Transformer

 

The Power Transformer is installed at various power stations for generation and transmission of power. It acts as a step-up or a step-down transformer for increasing and decreasing the level of voltages as per the requirement, and it’s also used as an interconnection between two power stations.

 

Distribution Transformer

 

The Distribution Transformer is used to bring down or step down the voltage and current level of a transmission line to a predefined level, which is called safety level for the end-user consumer in domestic and industrial purpose.

 

Key Difference Between Power Transformer and Distribution Transformer

 

Power transformers are used in the transmission network of higher voltages whereas the Distribution Transformers are used in the distribution network of lower voltages.

The power transformers are available in various ratings of 400 kV, 200 kV, 110 kV, 66 kV, 33 kV in the market and the distribution transformer are available in 11 kV, 6.6 kV, 3.3 kV, 440 V, 230 Volts.

 

The power transformer always operates on rated full load as the load fluctuation is very less but the distribution transformer is operated at the load less than full load as the variation in the loads are very high.

 

The power transformers are designed for maximum efficiency of 100%, and the efficiency is simply calculated by the ratio of output power to the input power, whereas the distribution transformer the maximum efficiency varies between 50-70% and calculated by All Day Efficiency.

 

Power transformers are used in power generating stations and transmission substations, and the distribution transformer is installed at the distribution stations from where the power is distributed for the industrial and domestic purposes.

 

The size of the power transformer is large as compared to the distribution transformers.

 

In Power Transformer, the iron and copper losses take place throughout the day but in distribution transformer, the iron loss takes place 24 hours i.e., throughout the day, and the copper losses depend on the load cycle.

 

In this way, a power transformer is differentiated from a distribution transformer.

 

If you want to download difference between power transformer and distribution transformer pdf, please click our website.

 

As a professional China power supplier transformer, Yuebian has advanced production equipment and a complete product inspection system. Our transformers have high mechanical strength, balanced ampere-turn distribution and good short-circuit resistance.

 


No comments:

Post a Comment

Difference Between Power Transformer and Distribution Transformer

  Difference Between Power Transformer and Distribution  Transformer Here we will discuss, the difference between distribution transformer a...